Contact Us  |  Privacy policy  |  Site map   
  LadyBug logo       Big Performance... small package...  
spacer gif spacer gif spacer gif spacer gif spacer gif spacer gif spacer gif
  Home       >
Products > LB589A 1-866-789-7111 (USA)    1-707-546-1050 (WW)
 
Shopping Cart icon  




     
LB589A USB CW Wide Dynamic Range PowerSensor+™
LB589A USB True RMS Average Wide Dynamic Range PowerSensor™ Lead time 12 weeks or less

The LB589A is a 10 MHz to 26.5 GHz wide dynamic range average power sensor capable of measuring CW, pulse, and other signals. With a VSWR of 1.2:1 and operation over a wide -55 dBm to +20 dBm dynamic range it offers users the highest performance average power measurement solution.

Users requiring peak and/or pulse measurements should order the LB679A. Users requiring pulse profiling should order the LB680A.


Required connector option:
Connector Type Gender Option Description
SMA - 50 ohm Male OSM
Female OSF
3.5 mm - 50 ohm Male 35M
Female 35F
Other Options Include:
Add connector. An additional connector of the same type may be ordered. This provides the user the ability to change out or replace connectors during development phases of a project. Once the device's connector has been removed and replaced with the same or different connector, the device's calibration and match are not guaranteed.
• Add male connector, option 20M
• Add female connector, option 20F
A connector can be changed in about 5 minutes.
Add recorder out, option 001. This option adds an optional output voltage that is proportional to the input power. The recorder output voltage ranges from zero to one volt and is proportional to input power level. The range of power levels represented by the voltage output is set by the user. The output is provided through the SMB connector that is located in the same position as the trigger in.
If the unit is ordered with both external hardware triggering and the recorder out options, the SMB connector is shared between the recorder out and trigger in functions. Trigger in and recorder out functions are mutually exclusive functions. As a result, when the unit's recorder output is turned on the trigger input is disabled.
Add external hardware triggering, option 003. Adds an external hardware input trigger and external hardware output trigger. Both trigger in and trigger out are SMB connectors. If the recorder out option is also present, the trigger in SMB connector is shared between trigger in and recorder out (see "Add recorder out"). As a result, when the unit's trigger input is turned on the recorder output is disabled.
Data sheet Return and refund policy
 
 




 
  bottom border gif       bottom border gif  
          LadyBug Technologies™ supplies RF and Microwave Test Equipment for use in Cellular, PCS, Radar, Satellite Systems and Component Test Systems.  
             
          LadyBug Technologies LLC